Product parameters
Equipment size: length 480mm * width 520mm * height 500mm
Equipment weight: approximately 30KG
Single machine efficiency: over 500pcs/h
Equipment induced cell scrap rate: below 0.001%
Machine induced defect rate: controlled below 0.001%
Equipment failure rate: 3%
Operation method: manual loading/unloading of battery cells
Control mode: manual, data upload possible
Number of equipment operators: 1 person
Adjustable measurement angle range: 5 °~25 °
Testing the length and width dimensions of more than 99% of cells/batteries used in fixtures
The replacement does not require calibration, with a resolution of 0.001mm (depending on the measuring instrument), an error of ± 0.02mm, and an actual measured GRR of ≤ 10%. The replacement time with the same test pressure is within 1 minute
The changeover time with test pressure changes is within 5 minutes; Test pressure adjustable from 100+20g to 600+50g
Non conductive marble or ZrO2 ceramic in contact with the product, aluminum oxidation treatment near the testing area
Requirements for surrounding environment: no corrosive gas, low dust